GYTA Kabel Technyske Gegevens
| Kabeltype | Fasertelling | Buizen | Fillers | Kabeldiameter mm | Kabelgewicht kg/km | Treksterkte Lange/Koarte Termyn N | Ferset tsjin ferpletterjen Lange/Koarte Termyn N/100mm | Bûgingsradius Statysk mm |
| GYTA-2~12 | 8~12 | 1 | 4 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-14~18 | 14~18 | 3 | 2 | 9.0 | 100 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-20~24 | 20~24 | 4 | 1 | 9.5 | 110 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-26~36 | 26~36 | 4 | 1 | 9.5 | 120 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-38~48 | 38~48 | 4 | 1 | 10.0 | 140 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-50~60 | 50~60 | 5 | 0 | 10.8 | 150 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-62~72 | 62~72 | 6 | 0 | 11.9 | 170 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-74~84 | 74~84 | 7 | 1 | 12.5 | 180 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-86~96 | 86~96 | 8 | 0 | 13.6 | 210 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-98~108 | 98~108 | 9 | 1 | 14.5 | 230 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-110~120 | 110~120 | 10 | 0 | 14.8 | 240 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTS-122~144 | 122~132 | 11 | 1 | 15.4 | 260 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-146~216 | 146~216 | 12 | 0 | 19.8 | 395 | 1000/3000 | 1000/3000 | 10D/20D |
| GYTA-218~288 | 218~288 | 12 | 0 | 20.8 | 470 | 1000/3000 | 1000/3000 | 10D/20D |
Fezelkarakteristyk:
| Fiberstyl | Ienheid | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Betingst | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Ferswakking | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Fersprieding | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Bânbreedte | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Nul ferspriedingsgolflingte | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Nul ferspriedingshelling | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| PMD Maksimale Yndividuele Faser | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD-ûntwerplinkwearde | Ps(nm²*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Fiber-ôfsnijgolflingte λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Kabelôfsnijing golflingte λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD | 1310nm | um | 9,2±0,4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10,4±0,8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numeryk Diafragma (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Stap (gemiddelde fan bidireksjoneel mjitting) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Unregelmjittichheden oer glêstriedlingte en punt | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Ferskil weromfersprieding koëffisjint | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Dempingsuniformiteit | dB/km | ≤0.01 | ≤0.01 | |||||
| Kearndiameter | um | 9 | 9 | 50±1.0 | 62,5±2,5 | 50±1.0 | 50±1.0 | |
| Diameter fan 'e bekleding | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Bekleding net-sirkelfoarmich | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Diameter fan 'e coating | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Bekleding/bokfink konsintryske flater | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Coating net-sirkulêr | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Konsentrisiteitsflater fan kearn/bekleding | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Krulling (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Kleur fan glêstried:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Blau | Oranje | Grien | Brún | Griis | Wyt |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Read | Swart | Giel | Fioeltsje | Rôze | Aqua |
GYTA-kabelbeskriuwing
+ De fezels, 250μm, binne pleatst yn in losse buis makke fan in plestik mei hege modulus.
+ De buizen binne fol mei in wetterbestindige fillingmix.
+ In stielen tried, soms omhuld mei polyetyleen (PE) foar kabel mei in hege fezeltelling, leit yn it sintrum fan 'e kearn as in metallysk sterkte-elemint.
+ Buizen (en fillers) binne om it sterkte-elemint stringen ta in kompakte en rûne kabelkearn.
+ InAluminium polyetyleen laminaat (APL)wurdt oanbrocht om de kabelkearn, dy't fol is mei de filling om it te beskermjen tsjin wetteryndringing.
+ De kabel is ôfmakke mei in PE-mantel.
Konstruksje:
GYTA-kabeleigenskippen:
+ Goede meganyske en temperatuerprestaasjes
+ Losse buis mei hege sterkte dy't hydrolysebestindich is
+ Spesjale buisfolming soarget foar in krityske beskerming fan glêstried
+ Spesjaal ûntworpen kompakte struktuer is goed yn it foarkommen fan krimpen fan losse buizen
+ PE-mantel beskermet kabel tsjin ultraviolette strieling
+ De folgjende maatregels wurde nommen om de kabel wetterdicht te meitsjen:
+ Stieltried brûkt as it sintrale sterkte-elemint
+ Losse buisfolmiddel
+ 100% kabelkearnvulling
+ 100% hifke foar ferstjoering.
+ Kabelhaspellingte: 1 km, 2 km, 3 km, 5 km
GYTA-kabelapplikaasje:
+ Oanpast foar distribúsje bûten.
+ Geskikt foar it lizzen fan pipelines, direkt begraven, ûndergrûnske metoade.
+ Kommunikaasje oer lange ôfstân en lokaal netwurk.
Ferpakking: