Distribúsje Fanout Tight Buffer Indoor Fiber Optical Cable (GJFJV)
Technyske parameters:
| Fanout Binnen glêstriedkabel (GJFJV) | Kabeldiameter | Gewicht | |
| 2 kearnen | 4,5 mm | 22,00 kg/km | |
| 4 kearnen | 4,5 mm | 22,00 kg/km | |
| 6 kearnen | 4,5 mm | 23,00 kg/km | |
| 8 kearnen | 5,5 mm | 27,00 kg/km | |
| 10 kearnen | 5,5 mm | 30,00 kg/km | |
| 12 kearnen | 6.0mm | 35,00 kg/km | |
| Opslachtemperatuer (℃) | -20+60 | ||
| Min. bûgingsradius (mm) | Lange termyn | 10D | |
| Min. bûgingsradius (mm) | Koarte termyn | 20D | |
| Min tastiene treksterkte (N) | Lange termyn | 200 | |
| Min tastiene treksterkte (N) | Koarte termyn | 600 | |
| Drukbelasting (N/100mm) | Lange termyn | 200 | |
| Drukbelasting (N/100mm) | koarte termyn | 1000 | |
Fezelkarakteristyk:
| Fiberstyl | Ienheid | SMG652 | SMG652D | SMG657A | MM50/125 | MM62.5/125 | MMOM3-300 | ||
| betingst | nm | 1310/1550 | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | ||
| ferswakking | dB/km | ≤0.36/0.23 | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ||
| Fersprieding | 1550nm | Ps/(nm*km) | ---- | ≤18 | ≤18 | ---- | ---- | ---- | |
| 1625nm | Ps/(nm*km) | ---- | ≤22 | ≤22 | ---- | ---- | ---- | ||
| Bânbreedte | 850nm | MHZ.KM | ---- | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ---- | ≥800 | ≥500 | ||||
| Nul ferspriedingsgolflingte | nm | ≥1302≤1322 | ≥1302≤1322 | ≥1302≤1322 | ---- | ---- | ≥ 1295,≤1320 | ||
| Nul ferspriedingshelling | nm | ≤0.092 | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ||
| PMD Maksimale Yndividuele Faser | ≤0.2 | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| PMD-ûntwerplinkwearde | Ps(nm²*km) | ≤0.12 | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ||
| Fiber-ôfsnijgolflingte λc | nm | ≥ 1180≤1330 | ≥1180≤1330 | ≥1180≤1330 | ---- | ---- | ---- | ||
| Kabelôfsnijinggolflingte λcc | nm | ≤1260 | ≤1260 | ≤1260 | ---- | ---- | ---- | ||
| MFD | 1310nm | um | 9,2±0,4 | 9,2±0,4 | 9.0±0.4 | ---- | ---- | ---- | |
| 1550nm | um | 10,4±0,8 | 10,4±0,8 | 10.1±0.5 | ---- | ---- | ---- | ||
| NumerykDiafragma (NA) | ---- | ---- | ---- | 0.200± 0.015 | 0.275±0.015 | 0.200±0.015 | |||
| Stap (gemiddelde fan bidireksjoneelmjitting) | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Unregelmjittichheden oer glêstriedlingte en punt | dB | ≤0.05 | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ||
| Underbrekking | |||||||||
| Ferskil weromferspriedingkoëffisjint | dB/km | ≤0.05 | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ||
| Dempingsuniformiteit | dB/km | ≤0.01 | ≤0.01 | ≤0.01 | |||||
| Kearndiameter | um | 9 | 9 | 9 | 50±1.0 | 62,5±2,5 | 50±1.0 | ||
| Diameter fan 'e bekleding | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | ||
| Bekleding net-sirkelfoarmich | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ||
| Diameter fan 'e coating | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | ||
| Bekleding/bokfinkkonsintryske flater | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ||
| Coating net-sirkulêr | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ||
| Konsentrisiteitsflater fan kearn/bekleding | um | ≤0.6 | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ||
| Krulling (radius) | um | ≤4 | ≤4 | ≤4 | ---- | ---- | ---- | ||
Kabelkonstruksjes:
Kabelútsnijing:
Multimode OM3 8-kearnen Kabel
Single-modus 4-kearnen Kabel
Multimode 50/125 24 kearnen Kabel
Beskriuwingen:
•De Distribution Fanout Tight Buffer Indoor Fiber Optical Cable brûkt 2~48 kearnen (of mear) en brûkt 900μm of 600μm tight buffer glêstried as optyske subkabel. Normaal wurdt it omhuld mei PVC of LSZH, mar ek mei PE of Nilon.
•De strakke bufferfaser ynpakt mei in laach aramidegaren as sterkte-lid, dan foltôge mei in laach PVC- of LSZH-materiaal as bûtenmantel.
•De Distribution Fanout Tight Buffer Indoor Fiber Optical Cable out jacket kleur:
Ienkele modus: Giel,
Multimodus OM1 / OM2: Oranje,
Multimodus OM3 / OM4: Aqua,
Multimodus OM4: Fiolet,
Multimode OM5: Lime.
Oare kleur is opsjoneel.
Oanfraach:
+ Gebrûkt yn pigtails en patchcords.
+ Brûkt as ferbiningslinen fan apparatuer, en brûkt yn optyske ferbiningen yn optyskekommunikaasjekeamers, datasintrums en optyske distribúsjeframes.
+ Gebrûkt yn binnenbekabeling, benammen brûkt as distribúsjekabel.
Karakteristiken:
•Goede meganyske en miljeu-eigenskippen.
•Flamfertragende skaaimerken foldogge oan de easken fan relevante noarmen.
•De meganyske eigenskippen fan 'e jacked foldogge oan 'e easken fan relevante noarmen.
•Sêft, fleksibel, maklik te lizzen en te splicen, en mei gegevensoerdracht mei grutte kapasiteit.
•Foldogge oan ferskate easken fan 'e merk en kliïnten.
Tapassing: brûkt foar binnenkabel fan-out multifaser pigtail/patchkabel
+ Gebrûkt yn pigtails en patchcords.
+ Brûkt as ferbiningslinen fan apparatuer, en brûkt yn optyske ferbiningen yn optyske
kommunikaasjekeamers en optyske distribúsjeframes.
+ Gebrûkt yn binnenbekabeling, foaral brûkt as distribúsjekabel.
Ferpakking: